<LOGO>
FM Transmitter Measurement Report
Created: 2024-02-01 10-00-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.60 MHz 5/5, 64 dBuV RTL2
Pilot RDS Phase Difference
6.8 kHz 4.1 kHz 35 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 68 kHz 19120 0,0366
Modulation Power
Limit Measuring Tolerance
9,0 dBr 1,0 dBr
MIN AVE MAX % above 10,0 dBr
5,2 dBr 6,27 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL2 " F215 0 (No PTY) 1 0 1 2 10:00, 1.02.2024
RT
-
AF EON
88.2, 94.4, 96.2, 96.4, 96.6, 98.0, 98.2, 105.1, 105.9, 106.0, 106.1 MHz -
FM Scope Station: 96.60 MHz, signal: 5/5 (64 dBuV) Max at: 68 kHz MIN: 10 kHz % above 75 kHz: 0,0366 Acquired: 2024/02/01 9:59:22 Total samples: 19120 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 6,7 dBr MIN: 5,2 dBr AVE: 6,27 dBr % above 10,0 dBr: 0,0 Last value: 5,3 dBr (2024/02/01 9:59:22) Station: 96.60 MHz, signal: 5/5 (64 dBuV) 09:46 09:48 09:50 09:52 09:54 09:56 09:58 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality